fall-preventionEN

๐Ÿšจ Red Flags: When to STOP the Orthostatic Assessment

SBP drop >40 mmHg sustained โ†’ Lower patient immediately, notify physician
Any symptoms + BP drop โ†’ Lower patient, do not continue
Near-syncope or syncope โ†’ Protect patient, call for help

HR fails to increase with standing โ†’ Suspect autonomic failure โ€” escalate

Patient safety ALWAYS comes before completing the test. You can repeat it. You can't undo a fall.